Determining the Minimum Number of IOP Measurements Necessary to Establish a Baseline IOP: A Statistical Approach         
Determining the Minimum Number of IOP Measurements Necessary to Establish a Baseline IOP: A Statistical Approach
作者:C.C. Ten… 文章来源:Ophthalmology, New York University, New York, NY, USA 2Economics, University of Southern Mississippi, Hattiesburg, MS, USA. Department of Ophthalmology, New York University Medical Center. 462 First Avenue, NBV 5N18, New York, NY 10016 点击数:1085 更新时间:2006/7/5 17:37:38
Purpose: The ability to set a therapeutic goal intraocular pressure (IOP) for a patient with glaucoma or ocular hypertension is predicated on an understanding of the patient’s baseline IOP. Thus, the appropriate determination of baseline IOP is essential. Although an accurate baseline IOP can be determined by obtaining a very large number of IOP measurements, this is impractical because a large number of examinations would represent a significant burden on both the clinician and patient and would result in a significant delay in therapy. We propose a statistical method to determine the minimum number of IOP measurements necessary to obtain an accurate baseline IOP. Methods: IOP’s of normal eyes were measured on consecutive visits using a single Goldmann applanation tonometer by a single examiner. Individual IOP measurements from a single eye were sequentially evaluated until a 95% confidence interval could be established about the sample mean within two levels of sampling error: +/- 1 mm Hg and +/- 2 mm Hg. The process was repeated for each of the 20 eyes in the study group. The number of IOP measurements required to satisfy the conditions of the 95% confidence interval was recorded for both levels of sampling error. Results: 20 eyes of 10 patients were enrolled. The larger sampling error of +/- 2 mm Hg yielded estimates in all 20 eyes examined. The number of measurements required to satisfy the conditions of the 95% confidence interval with a sampling error of +/- 2 mm Hg ranged between 2 and 7 with a mean of 2.8±1.1. When the mean baseline IOP estimates were compared to the means of the larger sample, the larger sample mean was correctly predicted in all 20 cases (100%). The narrower sampling error of +/- 1 mm Hg yielded estimates in 12 eyes examined. The number of measurements required to satisfy the conditions of the 95% confidence interval with a sampling error of +/- 1 mm Hg ranged between 2 and 7 with a mean of 3.2. When the mean baseline IOP estimates were compared to the means of the larger sample, the larger sample mean was correctly predicted in 7 cases (58%). When predictions in the narrower sampling error group were constrained to at least 3 measurements, 10 of 10 were predicted correctly (100%). Conclusions: The number of IOP measurements required to establish a baseline depends upon the variance of IOP readings of any particular eye, an important consideration for the clinician. Our method yields a minimum number of necessary measurements to establish a baseline IOP within a sampling error of +/- 2 mm Hg achievable within the constraints of clinical practice.
会议投稿录入:chenyouxin    责任编辑:毛进 
  • 上一篇会议投稿:

  • 下一篇会议投稿:
  • 【字体: 】【发表评论】【加入收藏】【告诉好友】【打印此文】【关闭窗口
      网友评论:(只显示最新10条。评论内容只代表网友观点,与本站立场无关!)

    | 设为首页 | 加入收藏 | 联系站长 | 友情链接 | 版权申明 |
    眼科医生网 眼科医生网版权所有 @ 1998-2012
    部分文章和资源来源于网络,如果侵犯了您的版权,请指出! 站长:毛进
    信息产业部备案
    *京ICP备18030162号